Raws li cov cuab yeej tseem ceeb hauv kev xa hluav taws xob thiab kev xa tawm, cov tshuab ziab khaub ncaws qhuav yog siv dav hauv kev lag luam, kev lag luam thiab pej xeem cov chaw vim nws txoj kev nyab xeeb, kev tiv thaiv ib puag ncig thiab kev saib xyuas tsis zoo. Ntawm lawv, 315 kva transformer, raws li tus qauv muaj peev xwm, tau nyiam los ntawm ntau tus neeg siv rau nws qhov kev ua haujlwm ruaj khov thiab siv dav. Kev soj ntsuam xyuas tsis tu ncua yog tus yuam sij los ua kom muaj kev nyab xeeb thiab ua haujlwm tau zooqhuav hom faib transformerthiab 315 kva transformer, uas tuaj yeem zam cov khoom siv tsis ua haujlwm thiab txuas ntxiv lub neej kev pabcuam. Tsab ntawv xov xwm no yuav nthuav dav txog kev soj ntsuam cov khoom ntawm cov tshuab ziab khaub ncaws qhuav, muab kev cob qhia rau cov neeg siv txawv teb chaws, thiab qhia txog cov khoom lag luam zoo ntawm JINShanMEN TECHNOLOGY CO., LTD.
I. Kev tshuaj xyuas qhov tshwm sim
Kev soj ntsuam zoo li no yog thawj kauj ruam ntawm kev soj ntsuam xyuas, uas tuaj yeem pom ncaj qha rau qhov pom tseeb qhov tsis raug thiab muaj peev xwm zais kev phom sij ntawm cov tshuab ziab khaub ncaws qhuav thiab 315 kva transformer. Nws feem ntau suav nrog kev tshuaj xyuas ntawm lub plhaub transformer, windings thiab insulating qhov chaw.
1. Transformer Plhaub tshuaj xyuas
Xyuas seb lub plhaub ntawm cov khoom siv hluav taws xob qhuav (xws li 315 kva transformer) puas yog deformed lossis puas. Piv txwv li, yog hais tias lub plhaub raug cuam tshuam los ntawm sab nraud quab yuam los yog corroded rau lub sij hawm ntev, nws yuav muaj kev nyuaj siab, tawg thiab lwm yam mob, uas yuav cuam tshuam rau lub zog txhua yam thiab kev tiv thaiv kev ua tau zoo ntawm lub transformer, thiab txawm yuav ua rau lub internal tivthaiv puas nyob rau hauv loj heev mob.
Saib seb qhov av ntawm lub plhaub puas zoo. Cov khoom siv hauv av yuav tsum ruaj khov, cov xaim hauv av yuav tsum tsis muaj kev tawg, xeb thiab lwm yam tshwm sim, thiab cov av tiv thaiv yuav tsum ua tau raws li cov kev cai ntawm cov qauv thoob ntiaj teb. Feem ntau, qhov kev tiv thaiv hauv av yuav tsum tsawg dua 4 ohms los xyuas kom meej tias tam sim no muaj kev nyab xeeb nkag mus rau hauv av thaum lub tshuab ziab khaub ncaws qhuav lossis 315 kva transformer tsis ua haujlwm, kom tsis txhob muaj kev sib tsoo hluav taws xob.
2. Windings thiab Insulators
Tshawb xyuas seb puas muaj cov xaim xaim nyob rau hauv windings ntawm qhuav hom faib transformer thiab 315 kva transformer. Nyob rau hauv ib txwm muaj xwm txheej, cov windings yuav tsum tau qhwv los ntawm cov ntaub ntawv insulating. Yog tias pom cov xov hlau raug pom, nws yuav ua rau luv luv Circuit Court, tawm hauv av thiab lwm yam txhaum, uas yuav cuam tshuam rau kev ua haujlwm ntawm cov khoom siv.
Tshawb xyuas seb cov insulators (xws li insulators, insulating cylinders, thiab lwm yam) puas huv, tawg lossis puas. Qhov saum npoo ntawm insulator yuav tsum du thiab tsis muaj av. Yog tias muaj plua plav lossis av ntau, qhov kev ua haujlwm rwb thaiv tsev yuav raug txo; ib zaug cov kab nrib pleb pom nyob rau hauv cov insulators, cov rwb thaiv tsev kev ua tau zoo yuav poob qis, uas yog ib qho yooj yim ua rau hluav taws xob faults, tshwj xeeb tshaj yog rau 315 kva transformer siv nyob rau hauv hnyav ib puag ncig.

II. Kev soj ntsuam kev ua haujlwm
Kev tshuaj xyuas kev ua haujlwm yog lub hauv paus ntawm kev soj ntsuam xyuas, uas tuaj yeem nkag siab lub sijhawm ua haujlwm tsis zoo ntawm cov khoom siv hluav taws xob qhuav thiab 315 kva transformer, thiab tshawb xyuas cov haujlwm tsis zoo. Nws feem ntau suav nrog kev tshuaj xyuas lub suab, qhov kub thiab txias, tam sim no thiab voltage.
1. Suab
Thaum lub tshuab hluav taws xob qhuav qhuav thiab 315 kva transformer nyob rau hauv ib txwm ua haujlwm, lawv yuav tawm suab me ntsis thiab zoo li "buzzing" suab, uas yog lub suab tsim los ntawm kev vibration ntawm cov tub ntxhais hlau nyob rau hauv qhov kev txiav txim ntawm alternating tam sim no. Yog hais tias lub suab dheev ua nrov nrov, nrog rau lub suab "buzzing" intensifying thiab suab nrov, tej zaum yuav yog hais tias lub qhuav hom tis transformer los yog 315 kva transformer yog overloaded los yog muaj ib lub zos luv luv Circuit Court nyob rau hauv; Yog tias muaj "squeaking" tawm suab, nws yuav yog qhov paug tawm hauv zos los ntawm inter-tig luv luv Circuit Court ntawm winding los yog rwb thaiv tsev puas, thiab yuav tsum tau kaw lub sij hawm soj ntsuam.
2. Kub
Txheeb xyuas qhov ntsuas kub ntawm cov cuab yeej ntawm cov khoom siv ziab qhuav thiab 315 kva transformer. Qhuav hom transformers feem ntau yog nruab nrog cov ntsuas kub, xws li cov ntsuas kub tsis kam lossis cov ntsuas kub siab. Nws yog ib qho tsim nyog los xyuas kom meej tias tus pas ntsuas kub ntsuas ib txwm pom, thiab qhov ntsuas kub tau qhia nyob rau hauv qhov kev tso cai. Feem ntau, qhov nruab nrab kub nce txwv ntawm winding ntawm qhuav hom faib transformer (thaum huab cua kub yog + 40 degree) yog 100K (Class F rwb thaiv tsev). Rau hom qhuav transformer nrog Class H rwb thaiv tsev, qhov siab tshaj plaws ntawm nws cov winding tuaj yeem ncav cuag 155℃lossis siab dua, tab sis qhov ntev -lub sij hawm ua haujlwm kub yuav tsum tau tswj nyob rau hauv qhov ntsuas ntau, tshwj xeeb tshaj yog rau 315 kva transformer nrog siab load rate.
Saib xyuas seb lub tshuab cua sov puas ua haujlwm li qub. Rau cov huab cua -txias qhuav hom faib transformer thiab 315 kva transformer, xyuas seb tus kiv cua puas khiav zoo li qub, seb puas muaj qhov rov qab tig, nres lossis suab nrov txawv txav. Yog tias tus kiv cua tsis ua haujlwm, cov cua kub dissipation yuav cuam tshuam, ua rau overheating ntawm transformer thiab shortening lub neej kev pab cuam.
3. Tam sim no thiab voltage
Saib xyuas cov kev tawm tswv yim thiab cov zis tam sim no thiab qhov hluav taws xob ntawm cov tshuab ziab khaub ncaws thiab 315 kva transformer los ntawm ammeters thiab voltmeters. Qhov tam sim no yuav tsum tsis txhob tshaj qhov ntsuas tam sim no ntawm lub transformer, thiab peb -theem tam sim no yuav tsum yog qhov sib npaug. Yog tias qhov tam sim no ntawm qee theem yog pom tseeb loj dhau, nws yuav yog tias cov theem dhau los lossis luv luv -circuited, uas yuav ua rau cov transformer windings puas.
Qhov voltage yuav tsum nyob rau hauv ± 5% ntawm qhov ntsuas voltage. Tsis tshua muaj siab lossis tsis tshua muaj hluav taws xob yuav tsis tsuas yog cuam tshuam rau kev ua haujlwm ib txwm muaj ntawm cov khoom siv qhuav faib transformer thiab315 kVA transformer 1, tab sis kuj puas lub transformer thiab cov khoom siv los ntawm nws, ua rau kev lag luam poob.

III. Kev soj ntsuam ib puag ncig
Kev khiav hauj lwm ib puag ncig ntawm qhuav hom faib transformer thiab 315 kva transformer muaj kev cuam tshuam zoo rau nws txoj haujlwm kev nyab xeeb thiab kev pabcuam lub neej. Ib puag ncig kev ua haujlwm zoo tuaj yeem txo qhov tsis ua haujlwm ntawm cov khoom siv. Kev tshuaj xyuas ib puag ncig feem ntau suav nrog qhov cua, qhov kub thiab txias, thiab ntsuas kev tiv thaiv kab mob nas.
1. Qhov cua txias
Xyuas seb qhov cua ntawm chav tsev transformer los yog installation txoj hauj lwm ntawm qhuav hom faib transformer thiab 315 kva transformer yog zoo. Cov tshuab ziab khaub ncaws qhuav yuav ua kom sov thaum lub sijhawm ua haujlwm, thiab qhov cua zoo tuaj yeem txo qhov kub ntawm lub transformer. Nws yog ib qho tsim nyog los xyuas kom meej tias lub qhov hluav taws xob qhov hluav taws xob tsis raug thaiv, cov kav dej tsis muaj kev puas tsuaj, thiab cov khoom siv cua xws li cov kiv cua lossis cov cua txias ua haujlwm zoo li qub, txhawm rau kom ntseeg tau tias cov cua sov dissipation cuam tshuam ntawm qhuav hom faib transformer thiab 315 kva transformer.
2. Kub thiab av noo
Qhov kub thiab av noo ntawm ib puag ncig ib puag ncig ntawm cov khoom siv hluav taws xob qhuav thiab 315 kva transformer kuj tseem ceeb heev. Kev kub siab ambient ntau dhau yuav ua rau cov cua sov ntawm lub tshuab hloov pauv, thiab cov av noo heev tuaj yeem ua rau qhov poob ntawm kev ua haujlwm rwb thaiv tsev, uas yooj yim ua rau hluav taws xob tsis zoo. Feem ntau, ambient kub yuav tsum tsis pub tshaj 40 degree, thiab tus txheeb ze av noo tsis ntau tshaj 85%. Nws yog qhov zoo tshaj rau nruab ib lub ntsuas kub thiab av noo rau tiag tiag- lub sijhawm saib xyuas kom kho qhov chaw nyob hauv lub sijhawm.
3. Kev tiv thaiv kab nas thiab kab tsuag
Xyuas seb puas muaj nas qhov lossis cov kab rau lwm cov tsiaj me nkag mus rau ib puag ncig ntawm cov khoom siv hluav taws xob qhuav thiab 315 kva transformer. Cov tsiaj me nkag mus yuav tom cov txheej txheem rwb thaiv tsev lossis cov xov hlau ntawm lub tshuab hloov pauv, ua rau luv luv thiab lwm yam tsis raug. Nyob rau tib lub sijhawm, xyuas seb puas muaj kab zes thiab lwm yam xwm txheej, ua kom qhov chaw nyob ib puag ncig ntawm lub tshuab ziab khaub ncaws qhuav thiab 315 kva transformer huv si thiab huv si, thiab tshem tawm cov kev phom sij zais.
Hais txog JINSHANMEN TECHNOLOGY CO., LTD
JINShanMEN TECHNOLOGY CO., LTD yog lub chaw tsim khoom ntawm cov khoom siv hluav taws xob sib txuas thiab xa tawm, nrog kev tsim khoom nplua nuj thiab kev siv tshuab siab heev. Lub tuam txhab tsuas yog tsim cov roj immersed fais fab transformers, qhuav- hom fais fab transformers, roj immersed peb-dimensional coiled fais fab transformers, qhuav-hom peb-dimensional coiled fais fab transformers, mining explosion- pov thawj qhuav-hom transformers ib tug fais fab tuag{8} explosion, mining transformers, nyob rau hauv load peev xwm tswj fais fab transformers, locomotive qhuav- hom transformers, raws li zoo raws li prefabricated substations, modular substations, cua zog lub thawv hom substations, siab thiab tsawg voltage switchgear thiab lwm yam kis tau tus mob thiab faib khoom. Peb cov tshuab ziab khaub ncaws qhuav thiab 315 kva transformer tau dhau qhov kev tshuaj xyuas nruj, ua raws li cov qauv thoob ntiaj teb, thiab raug xa tawm mus rau txawv teb chaws kev lag luam, yeej kev ntseeg siab ntawm cov neeg siv khoom ruaj khov thiab txhim khu kev qha zoo.
Kev soj ntsuam xyuas tsis tu ncua ntawm cov khoom siv hluav taws xob qhuav thiab 315 kva transformer yog ib qho kev ntsuas tseem ceeb los xyuas kom muaj kev nyab xeeb thiab ruaj khov ntawm lub zog hluav taws xob.JINSHANMEN TECHNOLOGY CO., LTDceeb toom rau txhua tus neeg siv kom ua raws li cov khoom tshuaj ntsuam xyuas saum toj no, ua kev soj ntsuam xyuas tsis tu ncua, nrhiav thiab daws qhov tsis raug raws sijhawm, thiab xyuas kom lub sijhawm ntev - lub sijhawm ua haujlwm ruaj khov ntawm cov cuab yeej siv. Yog tias koj xav yuav cov khoom siv hluav taws xob qhuav, 315 kva transformer lossis lwm yam khoom siv hluav taws xob xa tawm thiab xa tawm, thov hu rau peb, thiab peb yuav muab cov khoom zoo thiab cov kev pabcuam zoo rau koj.